- Set up the EVM as described in EVM Connections.
- Place a jumper on J2 (–VOUT
select) to set the output voltage to –12V.
- Set the load to constant
resistance or constant current mode to sink 0A.
- Increase the input voltage source
from 0V to 65V – |VOUT|; use voltmeter 1 to measure the input
voltage.
- Increase the current limit of the input supply to 8A.
- Use voltmeter 2 to measure the
output voltage. With an input voltage of 48V, vary the load current from 0A to
6A. VOUT must remain within the load regulation specification.
- Set the load current to 2A and
vary the input voltage source from 12V to (65V – |VOUT|).
VOUT must remain within the line regulation specification.
- Set the load current to 3.8A,
5.2A and 6A and measure the efficiency at typical input voltages of 12V, 24V,
and 48V, respectively.
- Decrease the load to 0A. Decrease
the input voltage source to 0V.
WARNING: Extended operation at high
output current can raise component and EVM board temperatures above 55°C. To avoid
risk of a burn injury, do not touch the components and the EVM board until cooled
sufficiently after disconnecting power.