SNOSDI6 October 2026 LMP8640-Q1
PRODUCTION DATA
While using a resistance of a known area of PCB trace or copper area as a sense resistor is a tempting strategy, for precision measurements this strategy is not recommended.
The temperature coefficient of copper is typically 3300-4000ppm/°K (0.33% to 0.4% per °C), which can vary with PCB processes.
A typical surface mount sense resistor temperature coefficient (tempco) is in the 50ppm to 500ppm per °C range offering more measurement consistency and accuracy over the copper trace. Special low tempco resistors are available in the 0.1 to 50ppm range, but at a much higher cost.