SNOSDI6 October 2026 LMP8640-Q1
PRODUCTION DATA
The value selected for the shunt resistor, RS, depends on the application. The shunt resistor plays a big role in a current sensing system and must be selected with care. The selection of the shunt resistor needs to take in account the tradeoffs in small-signal accuracy, the power dissipated and the voltage loss across the shunt.
In applications where a small current is sensed, a bigger value of RS is selected to minimize the error in the proportional output voltage. Higher resistor value improves the signal-to-noise ratio (SNR) at the input of the current sense amplifier and hence gives a more accurate output.
Similarly when high current is sensed, the power losses in RS can be significant so a smaller value of RS is desired. Taking into account the power rating of the Rs resistor is required in this condition. The low input offset of LMP8640-Q1 and LMP8640HV-Q1 allow the use of small sense resistors to reduce power dissipation still providing a good input dynamic range. The input dynamic range is the ratio between the maximum signal that can be measured and the minimum signal that can be detected, where typically the input offset is the principal limiting factor.
Figure 7-2 Example of a Kelvin (4-Wire) Connection to a Two-Terminal ResistorThe amplifier inputs must be directly connected to the sense resistor pads using “Kelvin” or “4-wire” connection techniques. The paths of the input traces must be identical, including connectors and vias, so that these errors are equal and cancel.