SNVSCK4B April 2024 – October 2025 TPS3842-Q1
PRODUCTION DATA
TPS3842-Q1 device offers built-in hysteresis around the UV threshold to avoid erroneous RESET/RESET. The hysteresis (VHYS) is added to the negative thresholds (VITN) and subtracted for positive thresholds (VITP).
| Part Number | DEVICE HYSTERESIS OPTION |
|---|---|
| TPS3842Axx1DRLRQ1 | 1% |
| TPS3842Axx5DRLRQ1 | 5% |
| TPS3842Axx0DRLRQ1 | 10% |
Hysteresis is dependent on the device VIT including VIT accuracy and deviations.
Undervoltage (UV)
VITN = 700mV
Voltage Hysteresis (VHYS) = 1% = VITN x 1% = 7mV
Release Voltage = VITN + VHYS = 707mV
Overvoltage (OV)
VITP = 700mV
Voltage Hysteresis (VHYS) = 1% = VITN x 1% = 7mV
Release Voltage = VITP - VHYS = 693mV