Shutdown Sequence

The waveform in Figure 3-2 shows the power-down sequence of the different power rails. In the waveform, 3V3 represents the VDDSHVx power supply grouping, 1V8_Main represents VDDSHVy, and 1V8_Analog represents VDDA_1P8. The PMP23242 board was blue wired to the SK-AM62A-LP evaluation board to confirm power-down sequence.

GUID-20230914-SS0I-JJZ2-B0D5-TBWQTQJX5L5D-low.pngFigure 3-2 Shutdown 1