TIDUDG1 July   2022

 

  1.   Description
  2.   Resources
  3.   Features
  4.   Applications
  5.   5
  6. 1System Description
  7. 2System Overview
    1. 2.1 Block Diagram
    2. 2.2 Design Considerations
      1. 2.2.1 MIL-STD-1275E versus MIL-STD-1275D
      2. 2.2.2 Reverse Polarity Event
      3. 2.2.3 Voltage Spike Event
      4. 2.2.4 Voltage Spike Event: Component Selection
      5. 2.2.5 Voltage Surge Event
      6. 2.2.6 Voltage Surge Event: Component Selection
    3. 2.3 Highlighted Products
      1. 2.3.1 LM7480-Q1
      2. 2.3.2 LM5069
  8. 3Hardware, Testing Requirements and Test Results
    1. 3.1 Hardware Requirements
    2. 3.2 Test Setup
    3. 3.3 Test Results
  9. 4Design and Documentation Support
    1. 4.1 Design Files
      1. 4.1.1 Schematics
      2. 4.1.2 BOM
    2. 4.2 Documentation Support
    3. 4.3 Support Resources
    4. 4.4 Trademarks

Test Setup

To test the TIDA-010242, TI partnered with NTS to do the MIL-STD-1275E electrical testing. All test setups for reverse polarity, voltage spike, and voltage surge testing were in accordance to the MIL-STD-1275E as outlined in the section about voltage compatibility verification. Please refer to the standard for more information.

The following images show the test setup diagrams.

Figure 3-2 Emitted Spike Test Setup
Figure 3-3 Injected Spike Test Setup
Figure 3-4 Surge Test Setup