TIDUF14 October   2022

 

  1.   Description
  2.   Resources
  3.   Features
  4.   Applications
  5.   5
  6. 1System Description
  7. 2System Overview
    1. 2.1 Block Diagram
    2. 2.2 Design Considerations
    3. 2.3 Highlighted Products
      1. 2.3.1 BQ76952
      2. 2.3.2 LM5163
      3. 2.3.3 MSP430FR2155
      4. 2.3.4 ISO1042
      5. 2.3.5 TPS54308
      6. 2.3.6 ISO7731
      7. 2.3.7 THVD1400
      8. 2.3.8 UCC27524
      9. 2.3.9 TMP61
  8. 3Hardware, Software, Testing Requirements, and Test Results
    1. 3.1 Hardware Requirements
    2. 3.2 Test Setup
    3. 3.3 Test Results
      1. 3.3.1 Cell Voltage Accuracy
      2. 3.3.2 Pack Current Accuracy
      3. 3.3.3 Auxiliary Power and System Current Consumption
      4. 3.3.4 Cell Balancing
      5. 3.3.5 Protection
      6. 3.3.6 Working Modes Transition
  9. 4Design and Documentation Support
    1. 4.1 Design Files
      1. 4.1.1 Schematics
      2. 4.1.2 BOM
    2. 4.2 Tools and Software
    3. 4.3 Documentation Support
    4. 4.4 Support Resources
    5. 4.5 Trademarks
  10. 5About the Author

Hardware Requirements

Table 3-2 summarizes the equipment used for testing.

Table 3-2 Test Equipment Summary
EQUIPMENT MODEL OR DESCRIPTION
Oscilloscope Tektronix DPO 2024B
DC Power supply Chroma 62050P-100-100
Electronic load Chroma 63106
Multimeter Agilent 34401A
DC Power supply DAHUA DH1718G-4
Communication adapter Texas Instruments EV2300 or EV2400
MSP430 programmer MSP430 LaunchPadâ„¢ Development Kit
ESD Simulator NoiseKen ESS-S3011

The Battery Management Studio (bqStudio) Software is recommended when debugging the board for the first time.