SNVS346G November 2007 – November 2023 LM3481
PRODUCTION DATA
When the voltage across the sense resistor (measured on the ISEN Pin) exceeds 220 mV, short-circuit current limit gets activated. A comparator inside the LM3481 reduces the switching frequency by a factor of 8 and maintains this condition until the short is removed.