SCAS542H October   1995  – February 2024 SN74AC573

PRODMIX  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Recommended Operating Conditions
    3. 5.3 Thermal Information
    4. 5.4 Electrical Characteristics
    5. 5.5 Timing Requirements, VCC = 3.3 V ± 0.3 V
    6. 5.6 Timing Requirements, VCC = 5 V ± 0.5 V
    7. 5.7 Switching Characteristics, VCC = 3 V ± 0.3 V
    8. 5.8 Switching Characteristics, VCC = 5 V ± 0.5 V
    9. 5.9 Operating Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Power Supply Recommendations
    2. 8.2 Layout
      1. 8.2.1 Layout Guidelines
      2. 8.2.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Receiving Notification of Documentation Updates
    2. 9.2 Support Resources
    3. 9.3 Trademarks
    4. 9.4 Electrostatic Discharge Caution
    5. 9.5 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • DB|20
  • RKS|20
  • NS|20
  • N|20
  • DW|20
  • PW|20
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS VCC TA = 25°C SN74AC573 UNIT
MIN TYP MAX MIN MAX
VOH IOH = −50 μA 3 V 2.9 2.9 V
4.5 V 4.4 4.4
5.5 V 5.4 5.4
IOH = −12 mA 3 V 2.58 2.48
IOH = −24 mA 4.5 V 3.94 3.8
5.5 V 4.94 4.8
IOH = −75 mA (1) 5.5 V 3.85
VOL IOL = 50 μA 3 V 0.1 0.1 V
4.5 V 0.1 0.1
5.5 V 0.1 0.1
IOL = 12 mA 3 V 0.36 0.44
IOL = 24 mA 4.5 V 0.36 0.44
5.5 V 0.36 0.44
IOL = 75 mA 5.5 V 1.65
II VI = VCC or GND 5.5 V ±0.1 ±1 μA
IOZ VO = VCC or GND 5.5 V ±0.25 ±2.5 μA
ICC VI = VCC or GND, IO = 0 5.5 V 4 40 μA
Ci VI = VCC or GND 5 V 5 pF
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.