over operating free-air temperature range (unless
otherwise noted)(1)
|
MIN |
MAX |
UNIT |
VCC |
Supply voltage |
–0.5 |
7 |
V |
VI |
Input voltage range(2) |
–0.5 |
7 |
V |
VO |
Output voltage range |
–0.5 |
VCC + 0.5 |
V |
IIK |
Input clamp current |
VI < 0 |
|
–20 |
mA |
IOK |
Output clamp current |
VO < 0 or VO >
VCC |
|
.
±20 |
mA |
IO |
Continuous output current |
VO = 0 to VCC |
|
±25 |
mA |
|
Continuous current through VCC or
GND |
|
±50 |
mA |
Tstg |
Storage temperature |
–65 |
150 |
°C |
(1) Stresses beyond those listed under
Absolute Maximum
Ratings may cause permanent damage to the device. These are stress
ratings only, and functional operation of the device at these or any other
conditions beyond those indicated under
Section 6.3 is not implied. Exposure to absolute-maximum-rated conditions for
extended periods may affect device reliability.
(2) The input and output negative-voltage ratings may be exceeded