SNLA431 January   2024 DP83TC812R-Q1 , DP83TC812S-Q1

 

  1.   1
  2.   Trademarks
  3. 1Preface
  4.   Notational Conventions
  5. 2Related Documentation
  6. 3Support Resources
  7. 4Troubleshooting the PHY Application
    1. 4.1  Schematic and Layout Checklist
    2. 4.2  Verify Successful Power-up of PHY
    3. 4.3  Peripheral Pin Checks
      1. 4.3.1 Probe the RESET_N pin
      2. 4.3.2 Probe the INH pin
      3. 4.3.3 Probe the CLKOUT pin
      4. 4.3.4 Probe the Serial Management Interface (MDC, MDIO) Pins
    4. 4.4  Register Dump Comparison
    5. 4.5  Verifying Strap Configurations
    6. 4.6  Check the MDI Signal
    7. 4.7  Link Up Failed Common Issues
    8. 4.8  Signal Quality Check
    9. 4.9  Power Up Timing
    10. 4.10 Loopback Testing
    11. 4.11 Debugging the MAC Interface
    12. 4.12 Verify Open Alliance PMA Compliance
    13. 4.13 Tools and References
      1. 4.13.1 DP83TC812 Register Access
      2. 4.13.2 DP83TC812 USB2MDIO Scripts
      3. 4.13.3 Extended Register Access
      4. 4.13.4 Software and Driver Debug on Linux
        1. 4.13.4.1 Commonly Seen Linux Terminal Outputs
  8. 5Conclusion

Link Up Failed Common Issues

Below are some common culprits if link up cannot be achieved.

  1. One link partner must be in MDI master mode while the other is in MDI slave mode. Verify this is the case by reading register 0x1834 on both PHYs.

  2. Unless link up is intended to be initially blocked upon power up of PHY, verify the device is in autonomous mode by confirming register 0x18B bit[6] = 1.

  3. Verify the PHY is not asleep by probing the INH pin and confirming the voltage is equal to Vsleep.

  4. Connect a different automotive ethernet cable to confirm the cable length, type, or health is not preventing the link up.

  5. Verify the script given in SNLA389 has been written to the PHY.