AFE4404
- Transmitter:
- Supports Common Anode LED Configuration
- Dynamic Range: 100 dB
- 6-Bit Programmable LED Current to 50 mA (Extendable to 100 mA)
- Programmable LED On-Time
- Simultaneous Support of 3 LEDs for Optimized SPO2, HRM, or Multi-Wavelength HRM
- Receiver:
- 24-Bit Representation of the Current Input from a Photodiode in Twos Complement Format
- Individual DC Offset Subtraction DAC at TIA Input for Each LED and Ambient Phase
- Digital Ambient Subtraction at ADC Output
- Programmable Transimpedance Gain:
10 kΩ to 2 MΩ - Dynamic Range: 100 dB
- Average Current Less Than 200 µA for PPG Signal Acquisition
- Pulse Frequency: 10 SPS to 1000 SPS
- Flexible Pulse Sequencing and Timing Control
- Flexible Clock Options:
- External Clocking:
4-MHz to 60-MHz Input Clock - Internal Clocking: 4-MHz Oscillator
- External Clocking:
- I2C Interface
- Operating Temperature Range: –20°C to 70°C
- 2.6-mm × 1.6-mm DSBGA Package, 0.5-mm Pitch
- Supplies: Rx: 2 V to 3.6 V, Tx: 3 V to 5.25 V,
IO: 1.8 V to 3.6 V
The AFE4404 is an analog front-end (AFE) for optical bio-sensing applications, such as heart-rate monitoring (HRM) and saturation of peripheral capillary oxygen (SpO2). The device supports three switching light-emitting diodes (LEDs) and a single photodiode. The current from the photodiode is converted into voltage by the transimpedance amplifier (TIA) and digitized using an analog-to-digital converter (ADC). The ADC code can be read out using an I2C interface. The AFE also has a fully-integrated LED driver with a 6-bit current control. The device has a high dynamic range transmit and receive circuitry that helps with the sensing of very small signal levels.
您可能會感興趣的類似產品
技術文件
類型 | 標題 | 日期 | ||
---|---|---|---|---|
* | Data sheet | AFE4404 Ultra-Small, Integrated AFE for Wearable, Optical, Heart-Rate Monitoring and Bio-Sensing datasheet (Rev. D) | PDF | HTML | 2016年 12月 1日 |
User guide | AFE4404 Development Guide (Rev. A) | 2015年 12月 17日 | ||
Technical article | Offset correction improves the next generation of heart-rate smart watches | PDF | HTML | 2015年 8月 24日 |
設計與開發
如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。
AFE4404EVM — 適用於穿戴式光學心率監測的 AFE4404 超小型整合式 AFE 評估模組
The AFE4404EVM is intended for evaluating TI's AFE4404 device. The fully integrated AFE is ideally suited for pulse oximeter and heart rate monitoring applications. It consists of a low noise receive channel and LED transmit section. The AFE4404 has a very highly configurable timing (...)
SLAC718 — AFE4404EVM Firmware Source v1.5
支援產品和硬體
產品
生物感測 AFE
硬體開發
開發板
SLAC704 — AFE4404EVM GUI v1.2.2
支援產品和硬體
產品
生物感測 AFE
硬體開發
開發板
PSPICE-FOR-TI — PSpice® for TI 設計與模擬工具
封裝 | 引腳 | 下載 |
---|---|---|
DSBGA (YZP) | 15 | 檢視選項 |
訂購與品質
- RoHS
- REACH
- 產品標記
- 鉛塗層/球物料
- MSL 等級/回焊峰值
- MTBF/FIT 估算值
- 材料內容
- 資格摘要
- 進行中可靠性監測
- 晶圓廠位置
- 組裝地點
建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。