SBOSAM3A July 2025 – August 2025 INA600
PRODMIX
The nominal performance of the INA600 is specified with a midsupply reference voltage from ±1.35 (2.7V) to ±20V (40V). The device also operates using non-midsupply reference voltages with good performance. Many specifications apply from –40°C to +125°C. The Electrical Characteristics table presents parameters that can exhibit significant variance because of operating voltage or temperature.
Add low-ESR ceramic bypass capacitors (CBYP) between each supply pin and ground. Only one CBYP is sufficient for single supply operation. Place the CBYP as close to the device as possible to reduce coupling errors from noisy or high-impedance power supplies. Verify the power supply trace routes through CBYP before reaching the amplifier power supply terminals. For more information, see the Layout Guidelines.