10 Revision History
Changes from Revision A (July 2024) to Revision B (January 2025)
- Updated the numbering format for tables, figures, and
cross-references throughout the documentsGo
- Added new spins ISO7742Tx-Q1Go
- Moved the HBM and CDM values from the Featues section to the ESD Ratings tableGo
- Changed CMTI TYP value from 75kV/μs to 100 kV/μs in all Electrical Characteristics tablesGo
- Added new Device ISO7742TxGo
- Changed the tDO TYP value from 6μs to 0.1μs and the MAX value from 9μs to 0.3μs in all Switching Characteristics tablesGo
Changes from Revision * (April 2024) to Revision A (July 2024)
- Updated the numbering format for tables, figures, and
cross-references throughout the documentsGo
- Changed minimum CMTI from 40 to 85 in all Electrical Characteristics tablesGo