10 Revision History
Changes from Revision H (November 2024) to Revision I (September 2026)
- Updated the certification information for VDE and IEC standards
throughout the documentGo
- Updated the Safety and Regulatory Approvals listGo
- Changed the Power Dissipation Characteristics section to the
Power Ratings sectionGo
- Updated the Insulation Specifications
sectionGo
- Updated the Safety-Related Certifications section to remove
content that is found in the associated certificatesGo
- Updated the Safety Limiting Values section to add links to thermal
derating curves and moved the curves to the new Insulation Characteristics
Curves sectionGo
- Added the Insulation Characteristics Curves
sectionGo
Changes from Revision G (July 2022) to Revision H (November 2024)
- Updated the numbering format for tables, figures, and
cross-references throughout the documentGo
- Added content from the High Voltage Feature Description
section to the Specifications sectionGo
- Changed the Regulatory Information Section to the
Safety-related Certifications section and moved to the
Specifications sectionGo
- Moved the Safety Limiting Values to the Specifications
sectionGo
Changes from Revision F (March 2016) to Revision G (July 2022)
- Updated the numbering format for tables, figures, and
cross-references throughout the document. Go
Changes from Revision E (December 2015) to Revision F (March 2016)
- Changed the Safety and Regulatory Approvals list of Section 1 Go
- Added Section 1 "TUV Certification per EN 61010-1 and EN 60950-1" Go
- Changed text in the first paragraph of the Description From:
"certifications according to VDE, CSA, and CQC". To: "certifications according
to VDE, CSA, CQC, and TUV." Go
- Added TUV to the Safety-Related Certifications section and Table 4. Deleted
Note 1 in Table 4 Go
- Changed Figure 7-3 Go
Changes from Revision D (July 2015) to Revision E (December 2015)
- Changed Section 1 From: 8000VPK VIOTM and 2121 VPK
VIORM Reinforced. To: 8000VPK
Reinforced...Go
- Added Section 1: DW Package Certifications Complete; DWW Certifications Planned Go
- Added text to the Description: and extra-wide body (DWW)
packages...Go
- Added package: Extra wide SOIC, DWW (16) to the Device
Information table Go
- Added the DWW pinout image Go
- Added the DWW package to the Section 5.4 Go
- Added the DWW package information to Safety-Related
CertificationsGo
- added DWW-16 package options to Safety Limiting Values
Go
- Changed the MIN value of CMTI in Section 5.9 table From: 70 To: 100kV/µs, deleted the TYP value of 100kV/µs Go
- Added the DW package value to the Supply Current section of the Section 5.9Go
- Added the DWW package value to the Supply Current section of the Section 5.9Go
- Changed the MIN value of CMTI in Section 5.10 table From: 70 To: 100kV/µs, deleted the TYP value of 100kV/µs Go
- Added the DW package value to the Supply Current section of the Section 5.10Go
- Added the DWW package value to the Supply Current section of the Section 5.10 Go
- Changed the MIN value of CMTI in Section 5.11 table From: 70 To: 100 kV/µs, deleted the TYP value of 100 kV/µs Go
- Added the DW package value to the Supply Current section of the Section 5.11Go
- Added the DWW package value to the Supply Current section of the Section 5.11 Go
- Added tPHZ, tPLZ, tPZH, and tPZL to Section 5.13Go
- Added tPHZ, tPLZ, tPZH, and tPZL to Section 5.14Go
- Added Figure 6-2 Go
- Changed Table 7-1 Go
- Added text to the Section 8.1 section: "isolation voltage per UL 1577." Go
Changes from Revision C (May 2015) to Revision D (July 2015)
- Added device ISO7821F to the datasheet Go
- Changed the Description to include: "default output is 'high'
for the ISO7821 device and 'low' for the ISO7821F device. Go
- Changed the Figure 3-1
Go
- Changed Figure 5-1, Added Figure 5-2Go
- Changed tPLH and tPHL From: 5.5V to 5V in Figure 5-8
Go
- Changed Figure 6-3 Go
- Changed the Section 7.2 Go
Changes from Revision B (April 2015) to Revision C (May 2015)
- Changed From: VCC1 and VCC2 To:
VCCI and VCCO, GND1 and GND2 To: GNDI and GNDO and
added Notes 1 and 2 in the Figure 3-1
Go
- Changed the MIN value of CMTI in Section 5.9 table From: 50 To: 70kV/µs Go
- Changed the MIN value of CMTI in Section 5.10 table From: 50 To: 70kV/µs Go
- Changed the MIN value of CMTI in Section 5.11 table From: 50 To: 70 kV/µs Go
- Added sentence "If the EN pin is available and low then the output goes to high impedance." to the Section 7.1 section Go
- Changed the Section 7.2 to include the EN pin on the Receiver sideGo
- Changed "ISO782W functional modes" To: "ISO7821DW functional modes" in Section 7.4Go
- Changed Table 7-1 title From: "Functional Table" To: "ISO7821DW Function Table"Go
- Added the Section 7.4.1 section Go
- Changed device number ISO7821 To: ISO7821DW in Figure 8-2Go
Changes from Revision A (December 2014) to Revision B (April 2015)
- Changed the document title From: "Channel Digital Isolator" To: "Channel 1/1 Digital Isolator" Go
- Added Section 1: 2.25V to 5.5V Level TranslationGo
- Changed the Safety and Regulatory Approvals list of Section 1 Go
- Changed text in the Description From: "This device is being
reviewed for reinforced isolation certification by VDE and CSA. To: "This device
has reinforced isolation certifications according to VDE, CSA, and
CQC."Go
- Added Note (3) to the Section 5.1 tableGo
- Changed Note (1) of the Section 5.3 table Go
- Changed columns VDE and CSA to Safety-Related CertificationsGo
- Changed title From: IEC Safety Limiting Values To: Safety Limiting
ValuesGo
- Changed the table in Safety Limiting Values, added IS DW-16
package optionsGo
- Changed Figure 5-1 Go
- Changed From: VCCX To: VCCO In VOH of the Section 5.9 table Go
- Changed From: VCCX To: VCCO In VI(HYS) of the Section 5.9 table Go
- Changed From: VCCX To: VCCI In IIH of the Section 5.9 table Go
- Changed From: VCCX To: VCCI In CMTI of the Section 5.9 table Go
- Changed From: VCCX To: VCCI In Supply Current, DC Signal of the Section 5.9 tableGo
- Changed Note (1) of the Section 5.9 table Go
- Changed From: VCCX To: VCCO In VOH of the Section 5.10 table Go
- Changed From: VCCX To: VCCO In VI(HYS) of the Section 5.10 table Go
- Changed From: VCCX To: VCCI In IIH of the Section 5.10 tableGo
- Changed From: VCCX To: VCCI In CMTI of the Section 5.10 table Go
- Changed From: VCCX To: VCCI In Supply Current, DC Signal of the Section 5.10 table Go
- Changed Note (1) of the Section 5.10 table Go
- Changed From: VCCX To: VCCO In VOH of the Section 5.11 table Go
- Changed From: VCCX To: VCCI In IIH of the Section 5.11 table Go
- Changed From: VCCX To: VCCI In Supply Current, DC Signal of the Section 5.11 table Go
- Changed Note (1) of the Section 5.11 table Go
- Changed Figure 6-1 Go
- Changed From: VCC1 To: VCCI in Figure 6-3 Go
- Changed Figure 6-4 Go
- Deleted INPUT-SIDE and OUTPUT-SIDE from columns 1 and 2 of Table 7-1 Go
- Changed Note (1) of Table 7-1 Go
- Changed the Section 8.1 sectionGo
- Changed the Section 8.2 section and Figure 8-1Go
- Added text and Figure 8-2 to the Section 8.2.2 section Go
Changes from Revision * (November 2014) to Revision A (December 2014)
- Changed From: A product preview that included only page 1 and the pinout section To:
A complete datasheet Go
- Changed From: VCCX To: VCCO In IOH and IOL of the Section 5.3 table Go
- Changed From: VCCX To: VCCI In VIH and VIL of the Section 5.3 table Go