SNVS470I January 2007 – November 2025 LM25576
PRODUCTION DATA
RT sets the oscillator switching frequency. Generally, higher frequency applications are smaller but have higher losses. Operation at 300 kHz was selected for this example as a reasonable compromise for both small size and high efficiency. The value of RT for 300 kHz switching frequency can be calculated as follows:

The nearest standard value of 21 kΩ was chosen for RT.