SLLSF83B May 2021 – July 2025 TCAN11623-Q1 , TCAN11625-Q1
PRODUCTION DATA
The TCAN1162x-Q1 has six modes: normal, standby, sleep, reset, fail-safe, and off mode. Operating mode selection is made via the nSLP input terminal in conjunction with supply conditions, temperature conditions, and wake events.
| BLOCK | NORMAL | STANDBY | RESET | SLEEP | FAIL-SAFE |
|---|---|---|---|---|---|
| VFLT | On | On | On | Off | Off |
| VLDO3 | On | On | On | Off | Off |
| INH | Active | Active | Active | Off | Off |
| Low Power CAN RX | Off | Active | Active | Active | Active(1) |
| nRST | VLDO3 | VLDO3 | Low | Off | VLDO3 |
| BLOCK | NORMAL | STANDBY | RESET | SLEEP | FAIL-SAFE |
|---|---|---|---|---|---|
| VCCOUT | On | On | On | Off | Off |
| INH | Active | Active | Active | Off | Off |
| Low Power CAN RX | Off | Active | Active | Active | Active(1) |
| nRST | VCCOUT | VCCOUT | Low | Off | VCCOUT |