SLVSHZ5 November 2026 TPS544628
ADVANCE INFORMATION
READ_IOUT is shown in Figure 7-27 and described in Table 7-36.
Return to the Summary Table.
Write Transaction: N/A
Read Transaction: Read Word
Data Format: LINEAR11
NVM Back-up: No
Updates: On-the-fly The READ_IOUT command returns the measured SW output current in Amperes. See Telemetry for more details.
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| EXPONENT | READ_IOUT | ||||||
| R-1Ah | R-XXh | ||||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| READ_IOUT | |||||||
| R-XXh | |||||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15-11 | EXPONENT | R | 1Ah | Linear format two's complement exponent of -6 resulting in an LSB of 0.015625A |
| 10-0 | READ_IOUT | R | X | Output current reading. Bit [10] is tied 0 because device does not support negative values. |