4 Revision History
Changes from D Revision (October 2014) to E Revision
-
Changed Features bullet text from "...Qualified.." to...Test Guidance.." and HBM classification level from "H2" to "H1C"Go
-
Moved Tstg spec to the Abs Max Ratings table per new data sheet standardGo
-
Changed "Handling Ratings" to "ESD Ratings" and HBM Value From "±2 kV" to "±1000 V".Go
-
Changed Electrical Characteristics condition statement to "This specification applies over the full recommended input voltage range VI = 2.7 V to 5.5 V and over the temperature range TJ = –40°C to 125°C unless otherwise noted. Typical values apply for VI = 3.6 V and TJ = 25°C."Go
-
Changed The specification applies over the full recommended input voltage range VI = 2.7 V to 5.5 V and over the temperature range TJ = –40 °C to 125°C unless otherwise noted. Typical values apply for VI = 3.6 V and TJ = 25°Go
-
Added Analog Supply Input Filter description Go
Changes from C Revision (March 2014) to D Revision
-
Global editorial changes bringing the datasheet into the new formatGo
-
Changed max. efficiency from 89% to 91% and from 81% to 85% Go
-
Deleted "Minimum 1.25 MHz"Go
-
Changed 1-µA shutdown current to typ. 0.2 µAGo
-
Relocated and renamed the pin Functions table Go
-
Added thermal pad to pin Functions Table.Go
-
Added Thermal Pad to Absolute Maximum Ratings. Added min./max. values where missingGo
-
Added V(VIN), V(INN), VNEG, VPOS, V(ENN), V(ENP), V(PSN) to Recommended Operating Conditions tableGo
-
Changed symbol names to JEDEC complianceGo
-
Added frequency and duty cycles to Switching Characteristics table. Removed from Electrical Characteristics tableGo
-
Added Rectifier Diode Selection GuideGo
-
Added P-MOSFET Selection GuideGo
Changes from B Revision (February 2013) to C Revision
-
Added "Electrical Characteristics tested over –40°C to 125°C Junction Temperature Range"Go
-
Deleted TA table rowGo
-
Changed INN to VINN, added pin names VIN and INNGo
-
Added pin name VPOSGo
-
Added pin name VNEGGo
-
Changed INP to VINP, added pin name INPGo
-
Changed "between pins OUTN to VINN" to "between pins OUTN to INN"Go
-
Added operating junction temperatureGo
-
Added "In applications where high power dissipation and/or poor package thermal resistance is present, the maximum ambient temperature may require derating. See Thermal Information for details."Go
-
Deleted "virtual" from "Operating virtual junction temperature range"Go
-
Changed Electrical Characteristics condition statement to "This specification applies over the full recommended input voltage range VI = 2.7 V to 5.5 V and over the temperature range TJ = TA = –40°C to 125°C unless otherwise noted. Typical values apply for VI = 3.6 V and TJ = TA = 25°C."Go
-
Changed ILIM,min = 1800 mA to 1700 mAGo
-
Deleted VPOS = 5 V (105°C) rowGo
-
Changed rDS(on)P,max (VPOS = 5 V) = 300 mΩ to 390 mΩGo
-
Changed rDS(on)P,max (VPOS = 10 V) = 200 mΩ to 230 mΩGo
-
Changed ILIMP,min = 1800 mA to 1700 mAGo
-
Changed ILIMP,max = 2200 mA to 2250 mAGo
-
Added TA = –40°C to 85°CGo
-
Changed minimum f = 1250 kHz to 1150 kHzGo
-
Editorially updated Block DiagramGo
-
Changed "The maximum recommended junction temperature (TJ) of the TPS65131-Q1 is 125°C." to "The recommended device junction temperature range, TJ, is -40°C to 125°C."Go
-
Changed RθJA = 37.8°C/W to RθJA = 34.1°C/WGo
-
Changed "Specified regulator operation is ensured to a maximum ambient temperature TA of 105°C." to "The recommended operating ambient temperature range for the device is TA = –40°C to 105°C."Go
-
Changed "Therefore, the maximum power dissipation is about 1058 mW" to "Use Equation 13 to calculate the maximum power dissipation, PDmax, as a function of TA. In this equation, use TJ = 125°C to operate the device within the recommended temperature range, use TJ = T(TS) to determine the absolute maximum threshold when the device might go into thermal shutdown."Go
-
Changed Equation 13Go
Changes from A Revision (November 2012) to B Revision
-
Changed CDM ESD rating from C3B to C4B.Go
Changes from * Revision (May 2012) to A Revision
-
Device is going from Preview to ProductionGo
-
Added thermal information table values.Go
-
Added VPOS = 5 V (105°C) row and values to Electrical Characteristics table.Go