JAJSKO1M December   2004  – January 2023 TLV1117

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 TLV1117C Electrical Characteristics
    6. 6.6 TLV1117I Electrical Characteristics
    7. 6.7 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 NPN Output Drive
      2. 7.3.2 Overload Block
      3. 7.3.3 Programmable Feedback
    4. 7.4 Device Functional Modes
      1. 7.4.1 Normal Operation
      2. 7.4.2 Operation With Low Input Voltage
      3. 7.4.3 Operation at Light Loads
      4. 7.4.4 Operation in Self Protection
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  9. Device and Documentation Support
    1. 9.1 ドキュメントの更新通知を受け取る方法
    2. 9.2 サポート・リソース
    3. 9.3 Trademarks
    4. 9.4 静電気放電に関する注意事項
    5. 9.5 用語集
  10. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • KVU|3
  • DRJ|8
  • DCY|4
  • KCS|3
  • KTT|3
  • KCT|3
サーマルパッド・メカニカル・データ
発注情報

TLV1117C Electrical Characteristics

TJ = 0°C to 125°C, all typical values are at TJ = 25°C (unless otherwise noted)
PARAMETERTEST CONDITIONS(1)MINTYPMAXUNIT
Reference voltage, VREFVIN – VOUT = 2 V, IOUT = 10 mA, TJ = 25°CTLV11171.2381.251.262V
VIN – VOUT = 1.4 V to 10 V, IOUT = 10 mA to 800 mA1.2251.251.27
Output voltage, VOUTVIN = 3.5 V, IOUT = 10 mA, TJ = 25°CTLV1117-151.4851.51.515
VIN = 2.9 V to 10 V, IOUT = 0 mA to 800 mA1.4551.51.545
VIN = 3.8 V, IOUT = 10 mA, TJ = 25°CTLV1117-181.7821.81.818
VIN = 3.2 V to 10 V, IOUT = 0 mA to 800 mA1.7461.81.854
VIN = 4.5 V, IOUT = 10 mA, TJ = 25°CTLV1117-252.4752.52.525
VIN = 3.9 V to 10 V, IOUT = 0 mA to 800 mA2.4502.52.550
VIN = 5 V, IOUT = 10 mA, TJ = 25°CTLV1117-333.2673.33.333
VIN = 4.75 V to 10 V, IOUT = 0 mA to 800 mA3.2353.33.365
VIN = 7 V, IOUT = 10 mA, TJ = 25°CTLV1117-504.9505.05.050
VIN = 6.5 V to 12 V, IOUT = 0 mA to 800 mA4.9005.05.100
Line regulationIOUT = 10 mA, VIN – VOUT = 1.5 V to 13.75 VTLV11170.035%0.2%
IOUT = 0 mA, VIN = 2.9 V to 10 VTLV1117-1516mV
IOUT = 0 mA, VIN = 3.2 V to 10 VTLV1117-1816
IOUT = 0 mA, VIN = 3.9 V to 10 VTLV1117-2516
IOUT = 0 mA, VIN = 4.75 V to 15 VTLV1117-3316
IOUT = 0 mA, VIN = 6.5 V to 15 VTLV1117-50110
Load regulationIOUT = 10 mA to 800 mA, VIN – VOUT = 3 VTLV11170.2%0.4%
IOUT = 0 mA to 800 mA, VIN = 2.9 VTLV1117-15110mV
IOUT = 0 mA to 800 mA, VIN = 3.2 VTLV1117-18110
IOUT = 0 mA to 800 mA, VIN = 3.9 VTLV1117-25110
IOUT = 0 mA to 800 mA, VIN = 4.75 VTLV1117-33110
IOUT = 0 mA to 800 mA, VIN = 6.5 VTLV1117-50115
Dropout voltage, VDO (2)IOUT = 100 mA1.11.2V
IOUT = 500 mA1.151.25
IOUT = 800 mA1.21.3
Current limitVIN – VOUT = 5 V, TJ = 25°C(3)0.81.21.6A
Minimum load currentVIN = 15 VTLV11171.75mA
Quiescent currentVIN ≤ 15 VAll fixed-voltage options510mA
Thermal regulation30-ms pulse, TA = 25°C0.010.1%/W
Ripple rejectionVIN – VOUT = 3 V, Vripple = 1 Vpp, f = 120 Hz6075dB
ADJ pin current80120μA
Change in ADJ pin currentVIN – VOUT = 1.4 V to 10 V, IOUT = 10 mA to 800 mA0.25μA
Temperature stabilityTJ = full range0.5%
Long-term stability1000 hrs, no load, TA = 125°C0.3%
Output noise voltage
(% of VOUT)
f = 10 Hz to 100 kHz0.003%
All characteristics are measured with a 10-μF capacitor across the input and a 10-μF capacitor across the output. Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible.
Dropout is defined as the VIN to VOUT differential at which VOUT drops 100 mV below the value of VOUT,
measured at VIN = VOUT(nom) + 1.5 V.
Current limit test specified under recommended operating conditions.