JAJSNI3D december   2021  – august 2023 TPS7A14

PRODUCTION DATA  

  1.   1
  2. 1特長
  3. 2アプリケーション
  4. 3概要
  5. 4Revision History
  6. 5Pin Configuration and Functions
  7. 6Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics
    7. 6.7 Typical Characteristics
  8. 7Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Excellent Transient Response
      2. 7.3.2 Global Undervoltage Lockout (UVLO)
      3. 7.3.3 Enable Input
      4. 7.3.4 Internal Foldback Current Limit
      5. 7.3.5 Active Discharge
      6. 7.3.6 Thermal Shutdown
    4. 7.4 Device Functional Modes
      1. 7.4.1 Normal Operation
      2. 7.4.2 Dropout Operation
      3. 7.4.3 Disable Mode
  9. 8Application and Implementation
    1. 8.1 Application Information
      1. 8.1.1  Recommended Capacitor Types
      2. 8.1.2  Input, Output, and Bias Capacitor Requirements
      3. 8.1.3  Dropout Voltage
      4. 8.1.4  Behavior During Transition From Dropout Into Regulation
      5. 8.1.5  Device Enable Sequencing Requirement
      6. 8.1.6  Load Transient Response
      7. 8.1.7  Undervoltage Lockout Circuit Operation
      8. 8.1.8  Power Dissipation (PD)
      9. 8.1.9  Estimating Junction Temperature
      10. 8.1.10 Recommended Area for Continuous Operation
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Examples
  10. 9Device and Documentation Support
    1. 9.1 Device Support
      1. 9.1.1 Development Support
        1. 9.1.1.1 Evaluation Module
      2. 9.1.2 Device Nomenclature
    2. 9.2 Documentation Support
      1. 9.2.1 Related Documentation
    3. 9.3 ドキュメントの更新通知を受け取る方法
    4. 9.4 サポート・リソース
    5. 9.5 Trademarks
    6. 9.6 静電気放電に関する注意事項
    7. 9.7 用語集
  11.   Mechanical, Packaging, and Orderable Information
    1. 10.1 Mechanical Data

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • DRV|6
  • YBK|6
サーマルパッド・メカニカル・データ
発注情報

Estimating Junction Temperature

The JEDEC standard now recommends the use of psi (Ψ) thermal metrics to estimate the junction temperatures of the LDO when in-circuit on a typical PCB board application. These metrics are not strictly speaking thermal resistances, but rather offer practical and relative means of estimating junction temperatures. These psi metrics are determined to be significantly independent of the copper-spreading area. The key thermal metrics (ΨJT and ΨJB) are used in accordance with Equation 7 and are given in the Electrical Characteristics table.

Equation 7. ΨJT : TJ = TT + ΨJT × PD and ΨJB : TJ = TB + ΨJB × PD

where:

  • PD is the power dissipated as explained in Equation 3 and the Power Dissipation (PD) section
  • TT is the temperature at the center-top of the device package
  • TB is the PCB surface temperature measured 1 mm from the device package and centered on the package edge