SBOK029D April   2018  – November 2023 TMP461-SP

 

  1.   1
  2.   TMP461-SP Single-Event Effects (SEE) Radiation Test Report
  3.   Trademarks
  4. 1Overview
  5. 2SEE Mechanisms
  6. 3Test Device and Test Board Information
  7. 4Irradiation Facility and Setup
  8. 5Results
    1. 5.1 SEL Results
    2. 5.2 SET Results
    3. 5.3 Event Rate Calculations
  9. 6Summary
  10.   A Confidence Interval Calculations
  11.   B References
  12.   Revision History

Summary

Radiation effects of remote and local digital temperature sensor TMP461-SP was studied. This device is latch-up immune up to 76.18 MeV. The SET study was done by monitoring the temperature readout using the MSP430 device and monitoring the temperature readout and logging the values using a GUI for each run. Importantly, there were no transients observed up to rail voltage.