SLVA275C january   2010  – may 2023 UCD9081

 

  1.   Abstract
  2.   Trademarks
  3. 1Introduction
  4. 2Hardware
    1. 2.1 Package: RHB (S-PQFP-N32), 32-Pin Plastic Quad Flatpack
    2. 2.2 Hardware and Pinout
    3. 2.3 Detailed Pin Descriptions
      1. 2.3.1 RST
      2. 2.3.2 SDA
      3. 2.3.3 SCL
      4. 2.3.4 ADDRx
      5. 2.3.5 ROSC
  5. 3Software
    1. 3.1 Data File Format
    2. 3.2 I2C Transactions
    3. 3.3 Device Version
    4. 3.4 Checksum
    5. 3.5 Sample Configuration Data File
      1. 3.5.1 Factory Default
      2. 3.5.2 EVM Default Configuration
    6. 3.6 I2C Write and Read Transaction Formats
      1. 3.6.1 I2C Write Transaction
      2. 3.6.2 I2C Read Transaction
    7. 3.7 Pseudo I2C Write and Read Transactions
      1. 3.7.1 UCD9081 I2C Transactions for Writing User Data and PARAMS
      2. 3.7.2 UCD9081 I2C Transactions for Reading User Data and PARAMS
  6. 4User Configuration
    1. 4.1 Configuration Parameter Memory Map
    2. 4.2 Configuration Parameter Detail
      1. 4.2.1  GpDir
      2. 4.2.2  NegateEnablePolarity
      3. 4.2.3  SeqEventPending
      4. 4.2.4  SequenceEventParameters
      5. 4.2.5  SequenceEventLink
      6. 4.2.6  SequenceEventData
      7. 4.2.7  DependencyMasks
      8. 4.2.8  UnderVoltageThresholds
      9. 4.2.9  OverVoltageThresholds
      10. 4.2.10 RampTime
      11. 4.2.11 OutOfRegulationWidth
      12. 4.2.12 UnsequenceTime
      13. 4.2.13 EnablePolarity
      14. 4.2.14 SaveRailLog
      15. 4.2.15 ReferenceSelect
      16. 4.2.16 LastUnusedSeq
      17. 4.2.17 IgnoreGlitchAlarms
      18. 4.2.18 IgnoreFlashErrorLog
      19. 4.2.19 Checksum
  7. 5Additional Considerations
    1. 5.1 Embedded Application
    2. 5.2 Timing
      1. 5.2.1 UCD9081 Startup
      2. 5.2.2 Clock Stretching After Flash Erase
      3. 5.2.3 Bit Timeout
      4. 5.2.4 Byte or Transaction Timeout
  8. 6References
  9. 7Revision History

SequenceEventData

The SequenceEventData field in the configuration parameters specifies the rail and GPO sequencing and shutdown parameters. The address map for these registers is as follows:

AddressSizeDefault ValueDescription
0xE09820xE005Rail 1 sequencing and shutdown parameters
0xE09A20xA005Rail 2 sequencing and shutdown parameters
0xE09C20xE032Rail 3 sequencing and shutdown parameters
0xE09E20xE033Rail 4 sequencing and shutdown parameters
0xE0A020xE033Rail 5 sequencing and shutdown parameters
0xE0A220xE035Rail 6 sequencing and shutdown parameters
0xE0A420xE035Rail 7 sequencing and shutdown parameters
0xE0A620x0000Rail 8 sequencing and shutdown parameters
0xE0A820x0000GPO1 sequencing and shutdown parameters
0xE0AA20x0000GPO2 sequencing and shutdown parameters
0xE0AC20x0000GPO3 sequencing and shutdown parameters
0xE0AE20x0000GPO4 sequencing and shutdown parameters

The format for each register is as follows. The value in the ENABLE field of the SequenceEventParameters register determines the measure represented by the value in the RAILDATA field of the SequenceEventData register.

GUID-410F9587-5822-4D92-9022-62992642FD2B-low.gif