SLVUCB3 March   2022

 

  1.   Trademarks
  2. 1Introduction
    1. 1.1 Related Documentation
  3. 2Schematics, Bill of Materials, and Layout
    1. 2.1 TPS3760EVM Schematic
    2. 2.2 TPS3760EVM Bill of Materials
    3. 2.3 Layout and Component Placement
  4. 3EVM Connectors
    1. 3.1 EVM Test Points
    2. 3.2 EVM Jumpers
  5. 4EVM Setup and Operation
    1. 4.1 Input Power (VDD)
    2. 4.2 SENSE1/SENSE2 Inputs
    3. 4.3 RESET1/RESET2 Outputs
    4. 4.4 Capacitor Time Delay Reset/MR
    5. 4.5 Capacitor Time Delay Sense/MR

EVM Test Points

Table 3-1 lists the test points and functional descriptions. All pins of the device are broken out to test points on the EVM.

Table 3-1 Test Points
Test Point NumberTest Point Silkscreen LabelFunctionDescription
TP1VSENSE2Connects to the input of SENSE2 with optional divider.Allows user to apply desired voltage to SENSE2 pin.
TP2VSENSE1Connects to the input of SENSE1 with optional divider.Allows user to apply desired voltage to SENSE1 pin.
TP3VAUX1Connects to RESET1 pin.Allows user to optionally add an external pull up rail for the RESET1 output.
TP4VAUX2Connects to RESET2 pin.Allows user to optionally add an external pull up rail for the RESET1 output.
TP5GNDConnects to ground.Allows user to use ground connections from multiple points.
TP6VDD Connects to VDD pin.Allows user to connect to the VDD pin of the device.
TP7VSENSE2_PINConnects to the input of SENSE2 directly.Allows user to connect directly to the SENSE2 pin of the device.
TP8VSENSE1_PINConnects to the input of SENSE1 directly.Allows user to connect directly to the SENSE1 pin of the device.
TP9 RESET1_PIN Connects to the RESET1 pin. Allows user to measure the RESET1 output voltage.
TP10 RESET2_PIN Connects to the RESET2 pin. Allows user to measure the RESET2 output voltage.
TP11 GND Connects to ground. Allows user to use ground connections from multiple points.
TP12 GND Connects to ground. Allows user to use ground connections from multiple points.
TP13 GND Connects to ground. Allows user to use ground connections from multiple points.