SNVU588A December 2017 – January 2022 TPS40345
| TEST POINT | LABEL | USE | SECTION |
|---|---|---|---|
| TP1 | VIN | Measurement test point for input voltage | 4.3.1 |
| TP2 | GND | Ground test point for input voltage | 4.3.1 |
| TP3 | VOUT | Measurement test point for output voltage | 4.3.1 |
| TP4 | GND | Ground test point for output voltage | 4.3.2 |
| TP5 | CHB | Measurement test point for channel B of loop response | 4.3.3 |
| TP6 | SGND | Ground test point for channel B of loop response | 4.3.3 |
| TP7 | CHA | Measurement test point for channel A of loop response | 4.3.3 |
| TP8 | SGND | Ground test point for channel A of loop response | 4.3.3 |
| TP9 | SGND | Ground test point for error amplifier measurements | 4.3.4 |
| TP10 | COMP | Measurement test point for error amplifier output voltage | 4.3.4 |
| TP11 | FB | Measurement test point for error amplifier input voltage | 4.3.4 |
| TP12 | HDRV | Measurement test point for high-side gate driver voltage | 4.3.5 |
| TP13 | SW | Measurement test point for switching node voltage | 4.3.5 |
| TP14 | LDRV | Measurement test point for low-side gate driver voltage | 4.3.5 |
| TP15 | PGND | Ground test point for switch node and gate drive voltages | 4.3.5 |
| TP16 | PGOOD | Measurement test point for power good | 4.3.6 |
| TP17 | EN/SS | Measurement test point for enable / soft start | 4.3.7 |
| TP18 | SGND | Ground test point for power good and enable / soft start | 4.3.6 and 4.3.7 |