| PARAMETER | MIN | MAX | UNIT | ||
|---|---|---|---|---|---|
| ƒclock | Clock frequency, TCK | 20 | MHz | ||
| tclock | Clock period, TCK | 50 | ns | ||
| tw(H) | Pulse duration low, TCK | 50% reference points | 23 | ns | |
| tw(L) | Pulse duration high, TCK | 50% reference points | 27 | ns | |
| ts | Setup time – TDI valid before TCK↑ | 50% reference points | 10 | ns | |
| th | Hold time – TDI valid after TCK↑ | 50% reference points | 10 | ns | |
| ts | Setup time – TMS1 valid before TCK↑ | 50% reference points | 10 | ns | |
| th | Hold time – TMS1 valid after TCK↑ | 50% reference points | 10 | ns | |
| tt | Transition time (tr and tf) | 20% to 80% reference points | 3 | ns | |
| tdelay | Output delay, TCK↓ to TDO1 | 60pF load | 0 | 15 | ns |
Figure 5-20 Timing Diagram for JTAG Boundary Scan