SBAS535D August 2013 – June 2026 ADS1120
PRODUCTION DATA
The device has four 8-bit configuration registers that are accessible through the serial interface using the RREG and WREG commands. After power-up or reset, all registers are set to the default values (which are all 00h). All registers retain the values during power-down mode. Table 8-8 shows the register map of the configuration registers.
| REGISTER (Hex) | BIT 7 | BIT 6 | BIT 5 | BIT 4 | BIT 3 | BIT 2 | BIT 1 | BIT 0 |
|---|---|---|---|---|---|---|---|---|
| 00h | MUX[3:0] | GAIN[2:0] | PGA_BYPASS | |||||
| 01h | DR[2:0] | MODE[1:0] | CM | TS | BCS | |||
| 02h | VREF[1:0] | 50/60[1:0] | PSW | IDAC[2:0] | ||||
| 03h | I1MUX[2:0] | I2MUX[2:0] | DRDYM | RESERVED | ||||