SBAS535D August 2013 – June 2026 ADS1120
PRODUCTION DATA
As shown in Figure 9-12, the power-supply ramp rate must be monotonic and slower than 1V per 50µs for proper device power-up over the entire temperature range.
Figure 9-12 Power-Supply Ramp Rate