Table 8-4 shows the actual conversion times for each data rate setting. The values provided are in terms of t(CLK) cycles using an external clock with a clock frequency of fCLK = 4.096MHz. The data rates scale proportionally in case an external clock with a frequency other than 4.096MHz is used.
Continuous-conversion mode data rates are timed from one DRDY falling edge to the next DRDY falling edge. The first conversion starts 210 × tCLK (normal mode, duty-cycle mode) or 114 × tCLK (turbo mode) after the last SCLK falling edge of the START/SYNC command.
Single-shot conversion mode data rates are timed from the last SCLK falling edge of the START/SYNC command to the DRDY falling edge and rounded to the next tCLK. In case the internal oscillator is used, an additional oscillator wake-up time of up to 50µs (normal mode, duty-cycle mode) or 25µs (turbo mode) must be added in single-shot conversion mode. The internal oscillator starts to power up at the first SCLK rising edge of the START/SYNC command. If an SCLK frequency higher than 160kHz (normal mode, duty-cycle mode) or 320kHz (turbo mode) is used, the oscillator can possibly not be fully powered up at the end of the START/SYNC command. The ADC then waits until the internal oscillator is fully powered up before starting a conversion.
Single-shot conversion times in duty-cycle mode are the same as in normal mode. See the Duty-Cycle Mode section for more details on duty-cycle mode operation.
| NOMINAL DATA RATE (SPS) |
–3dB BANDWIDTH (Hz) |
ACTUAL CONVERSION TIME (t(CLK)) | |
|---|---|---|---|
| CONTINUOUS CONVERSION MODE | SINGLE-SHOT CONVERSION MODE | ||
| Normal Mode | |||
| 20 | 13.1 | 204768 | 204850 |
| 45 | 20.0 | 91120 | 91218 |
| 90 | 39.6 | 46128 | 46226 |
| 175 | 77.8 | 23664 | 23762 |
| 330 | 150.1 | 12464 | 12562 |
| 600 | 279.0 | 6896 | 6994 |
| 1000 | 483.8 | 4144 | 4242 |
| Duty-Cycle Mode | |||
| 5 | 13.1 | 823120 | n/a |
| 11.25 | 20.0 | 364560 | n/a |
| 22.5 | 39.6 | 184592 | n/a |
| 44 | 77.8 | 94736 | n/a |
| 82.5 | 150.1 | 49936 | n/a |
| 150 | 279.0 | 27664 | n/a |
| 250 | 483.8 | 16656 | n/a |
| Turbo Mode | |||
| 40 | 17.1 | 102384 | 102434 |
| 90 | 39.9 | 45560 | 45618 |
| 180 | 79.2 | 23064 | 23122 |
| 350 | 155.6 | 11832 | 11890 |
| 660 | 300.3 | 6232 | 6290 |
| 1200 | 558.1 | 3448 | 3506 |
| 2000 | 967.6 | 2072 | 2130 |
Even though the conversion time at the 20SPS setting is not exactly 1 / 20Hz = 50ms, this discrepancy does not affect the 50Hz or 60Hz rejection. To achieve the 50Hz and 60Hz rejection specified in the Electrical Characteristics, the external clock frequency must be 4.096MHz. When using the internal oscillator, the conversion time and filter notches vary by the amount specified in the Electrical Characteristics table for oscillator accuracy.