SBASAD1A December 2023 – May 2024 ADC3910D025 , ADC3910D065 , ADC3910D125 , ADC3910S025 , ADC3910S065 , ADC3910S125
PRODUCTION DATA
The device is primarily configured and controlled using the serial programming interface (SPI). After initial power up, the default operating configuration is shown in Table 6-4.
| FEATURE | DEFAULT |
|---|---|
| Signal Input | Differential |
| Reference | Internal |
| Channel Corrections | Disabled |
| Decimation | Disabled |
| Comparators | Disabled |
| Statistics Engine | Disabled |
| Interface | DDR, 10 lanes |
| Output Format | Two's Complement |