SBOS527G December   2010  – September 2025 TMP411-Q1 , TMP411D-Q1

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics (TMP411-Q1)
    6. 6.6  Electrical Characteristics (TMP411D-Q1)
    7. 6.7  Timing Characteristics
    8. 6.8  Timing Diagrams
    9. 6.9  Typical Characteristics (TMP411-Q1)
    10. 6.10 Typical Characteristics (TMP411D-Q1)
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Series Resistance Cancellation
      2. 7.3.2 Differential Input Capacitance
      3. 7.3.3 Temperature Measurement Data
      4. 7.3.4 THERM (PIN 4) and ALERT/ THERM2 (PIN 6)
      5. 7.3.5 Sensor Fault
      6. 7.3.6 Undervoltage Lockout (TMP411-Q1 Only)
      7. 7.3.7 Filtering
    4. 7.4 Device Functional Modes
      1. 7.4.1 Shutdown Mode (SD)
      2. 7.4.2 One-Shot Conversion
    5. 7.5 Programming
      1. 7.5.1  Serial Interface
      2. 7.5.2  Bus Overview
      3. 7.5.3  Timing Diagrams
      4. 7.5.4  Serial Bus Address
      5. 7.5.5  Read/Write Operations
      6. 7.5.6  Time-Out Function
      7. 7.5.7  High-Speed Mode
      8. 7.5.8  General-Call Reset
      9. 7.5.9  Software Reset
      10. 7.5.10 SMBUS Alert Function
  9. Register Map
    1. 8.1  Register Information
    2. 8.2  Pointer Register
    3. 8.3  Temperature Registers
    4. 8.4  Limit Registers
    5. 8.5  Status Register
    6. 8.6  Configuration Register
    7. 8.7  Resolution Register
    8. 8.8  Conversion Rate Register
    9. 8.9  N-factor Correction Register
    10. 8.10 Minimum and Maximum Registers
    11. 8.11 Consecutive Alert Register
    12. 8.12 THERM Hysteresis Register
    13. 8.13 Identification Registers
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

THERM Hysteresis Register

The THERM Hysteresis Register, shown in Table 8-9, stores the hysteresis value used for the THERM pin alarm function. This register must be programmed with a value that is less than the Local Temperature High Limit Register value, Remote Temperature High Limit Register value, Local THERM Limit Register value, or Remote THERM Limit Register value; otherwise, the respective temperature comparator does not trip on the measured temperature falling edges. Allowable hysteresis values are shown in Table 8-8. The default hysteresis value is 10°C, whether the device is operating in the standard or extended mode setting.

Table 8-8 Allowable THERM Hysteresis Values
TEMPERATURE
(°C)
THERM HYSTERESIS VALUES
TH[11:4]
(STANDARD BINARY)
(HEX)
00000 000000
10000 000101
50000 010105
100000 10100A
250001 100119
500011 001032
750100 10114B
1000110 010064
1250111 11017D
1270111 11117F
1501001 011096
1751010 1111AF
2001100 1000C8
2251110 0001E1
2551111 1111FF
Table 8-9 THERM Hysteresis Register Format
THERM HYSTERESIS REGISTER (Read = 21h, Write = 21h, POR = 0Ah)
BIT #D7D6D5D4D3D2D1D0
BIT NAMETH11TH10TH9TH8TH7TH6TH5TH4
POR VALUE00001010