SBOS844D May 2021 – August 2025 INA234
PRODUCTION DATA
The shunt calibration register needs to be correctly programmed at each VS power up for the device to properly report any result based on current. The first step is to calculate the minimum LSB value for the current by using Equation 2. Applying this equation with the maximum expected current of 10A results in an minimum LSB size of 4.8828125mA. The INA234 allows selection of the CURRENT_LSB to be up to 8x larger than the minimum LSB size. For this example a value of 5mA is used. Applying Equation 1 to the Current_LSB and selected value for the shunt resistor results in a shunt calibration register setting of 2048d (800h). Failure to set the value of the shunt calibration register results in a zero value for any result based on current. Programming this register is not required for reading shunt voltage, bus voltage, or setting alert limits.