Product details

Common-mode voltage (max) (V) 28 Common-mode voltage (min) (V) -0.3 Digital interface I2C Resolution (Bits) 12 Input offset (±) (max) (µV) 100 Input offset drift (±) (max) (µV/°C) 0.5 Voltage gain (V/V) 1 CMRR (min) (dB) 100 Iq (max) (mA) 0.5 Gain error (%) 0.5 Gain error drift (±) (max) (ppm/°C) 50 Features Alert Function, Bidirectional, Integrated Power Monitor, Low-side Capable Number of channels 1 Power measurement accuracy (%) 1 Rating Catalog Operating temperature range (°C) -40 to 125
Common-mode voltage (max) (V) 28 Common-mode voltage (min) (V) -0.3 Digital interface I2C Resolution (Bits) 12 Input offset (±) (max) (µV) 100 Input offset drift (±) (max) (µV/°C) 0.5 Voltage gain (V/V) 1 CMRR (min) (dB) 100 Iq (max) (mA) 0.5 Gain error (%) 0.5 Gain error drift (±) (max) (ppm/°C) 50 Features Alert Function, Bidirectional, Integrated Power Monitor, Low-side Capable Number of channels 1 Power measurement accuracy (%) 1 Rating Catalog Operating temperature range (°C) -40 to 125
DSBGA (YBJ) 8 0.2316 mm² (1.2 mm × 0.193 mm)
  • High-side or low-side current sensing
  • Operates from a 1.7V to 5.5V power supply
  • Reports current, voltage and power
  • Programmable full scale range: 20mV / 80mV
  • Input common mode range: –0.3V to 28V
  • Current monitoring accuracy:
    • 12-bit ADC resolution
    • 0.5% gain error (maximum)
    • 100µV offset (maximum)
  • Low input bias current: 10nA (maximum)
  • Configurable averaging options
  • General call addressing allows conversion synchronization among devices
  • Alert limits for over and under current events
  • 1.2V compliant I2C, SMBus interface
  • Two device address options with a 4-pin selectable address
  • DSBGA-8 Package (0.745mm × 1.508mm)
  • Operating temperature: –40°C and +125°C
  • High-side or low-side current sensing
  • Operates from a 1.7V to 5.5V power supply
  • Reports current, voltage and power
  • Programmable full scale range: 20mV / 80mV
  • Input common mode range: –0.3V to 28V
  • Current monitoring accuracy:
    • 12-bit ADC resolution
    • 0.5% gain error (maximum)
    • 100µV offset (maximum)
  • Low input bias current: 10nA (maximum)
  • Configurable averaging options
  • General call addressing allows conversion synchronization among devices
  • Alert limits for over and under current events
  • 1.2V compliant I2C, SMBus interface
  • Two device address options with a 4-pin selectable address
  • DSBGA-8 Package (0.745mm × 1.508mm)
  • Operating temperature: –40°C and +125°C

The INA234 device is a 12-bit digital current monitor with an I2C/SMBus-compatible interface that is compliant with a wide range of digital bus voltages such as 1.2V, 1.8V, 3.3V, and 5V. The device monitors the voltage across an external sense resistor and reports values for current, bus voltage, and power.

The INA234 features programmable ADC conversion times and averaging. The device also has a programmable calibration value with an internal multiplier that enables direct readouts of current in amperes and power in watts. The device monitors the bus voltage present on the IN– pin and can alert on overcurrent and undercurrent conditions as well as overvoltage and undervoltage conditions. High input impedance while in current measurement mode allows use of larger current sense resistors needed to measure small value system currents.

The INA234 senses current on common-mode bus voltages that can vary from –0.3V to 28V, independent of the supply voltage. The device operates from a single 1.7V to 5.5V supply, drawing a typical supply current of 300µA in normal operation. The device can be placed in a low-power standby mode where the typical operating current is 2.2µA.

The INA234 device is a 12-bit digital current monitor with an I2C/SMBus-compatible interface that is compliant with a wide range of digital bus voltages such as 1.2V, 1.8V, 3.3V, and 5V. The device monitors the voltage across an external sense resistor and reports values for current, bus voltage, and power.

The INA234 features programmable ADC conversion times and averaging. The device also has a programmable calibration value with an internal multiplier that enables direct readouts of current in amperes and power in watts. The device monitors the bus voltage present on the IN– pin and can alert on overcurrent and undercurrent conditions as well as overvoltage and undervoltage conditions. High input impedance while in current measurement mode allows use of larger current sense resistors needed to measure small value system currents.

The INA234 senses current on common-mode bus voltages that can vary from –0.3V to 28V, independent of the supply voltage. The device operates from a single 1.7V to 5.5V supply, drawing a typical supply current of 300µA in normal operation. The device can be placed in a low-power standby mode where the typical operating current is 2.2µA.

Download View video with transcript Video

Technical documentation

Design & development

For additional terms or required resources, click any title below to view the detail page where available.

Evaluation board

INA234_236EVM — INA232, INA234 and INA236 evaluation module for current/voltage/power monitors

This evaluation module (EVM) is an easy-to-use platform to evaluate the main features and performance of the INA232, INA234 or INA236. The EVM comes with GUI support to read and write to device registers.
User guide: PDF | HTML
Supported products & hardware
IDE, configuration, compiler or debugger

ASC-STUDIO-INA234 — ASC Studio (SysConfig) for configuring all aspects of the INA234 digital power monitor

SysConfig can be used to help simplify configuration challenges and accelerate software development with the INA234 digital power monitor.
Supported products & hardware
Calculation tool

ANALOG-ENGINEER-CALC — PC software analog engineer's calculator

The analog engineer’s calculator is designed to speed up many of the repetitive calculations that analog circuit design engineers use on a regular basis. This PC-based tool provides a graphical interface with a list of various common calculations ranging from setting operational-amplifier (...)

Supported products & hardware
Calculation tool

CS-AMPLIFIER-ERROR-TOOL — Current Sense Amplifier Comparison and Error Tool

This Excel calculator provides a comparison between two and five of our standard current sense amplifiers, delivering a chart containing the basic parameters of each device. This calculator also takes system condition inputs from users such as common-mode voltage, supply voltage, shunt resistor (...)
Supported products & hardware
Calculation tool

SBOR021 — Power Monitor Tool

Supported products & hardware
Package Pins CAD symbols, footprints & 3D models
DSBGA (YBJ) 8 Ultra Librarian

Ordering & quality

Support & training

TI E2E™ forums with technical support from TI engineers

Content is provided "as is" by TI and community contributors and does not constitute TI specifications. See terms of use.

If you have questions about quality, packaging or ordering TI products, see TI support. ​​​​​​​​​​​​​​

Video series

View all videos

Videos