SBOSAA6B May 2024 – July 2025 INA790A , INA790B
PRODUCTION DATA
For this application, the INA790x measures current in the driver circuit of a 12V, 1A hydraulic valve.
| DESIGN PARAMETER | EXAMPLE VALUE |
|---|---|
| Common-mode voltage | 12V |
| Maximum sense current | 1A |
| Power-supply voltage | 5V |