SBVS425B December 2022 – June 2025 TPS748A-Q1
PRODUCTION DATA
By using the thermal metrics ΨJT and ΨJB, the junction temperature is estimated with corresponding formulas (given in Equation 6); see the Thermal Information table. For backwards compatibility, an older θJC(top) parameter is listed as well.

where:
For more information about measuring TT and TB, see the Using New Thermal Metrics application note, available for download at www.ti.com.
For a more detailed discussion of why TI does not recommend using θJC(top) to determine thermal characteristics, see the Using New Thermal Metrics application note. For further information, see the Semiconductor and IC Package Thermal Metrics application note. Both application notes are available for download at www.ti.com