over operating free-air temperature range for
VCCA = 4.5V to 5.5V (unless otherwise noted)(1)
|
MIN |
MAX |
UNIT |
| VCCA |
Supply voltage range |
–0.5 |
6.5 |
V |
| VI |
Input voltage range |
A port(2) |
–0.5 |
VCCA + 0.5 |
V |
| Control
inputs |
–0.5 |
6 |
| VO |
Output
voltage range |
A port(2) |
–0.5 |
VCCA + 0.5 |
V |
| IIK |
Input
clamp current |
VI < 0 |
|
–50 |
mA |
| IOK |
Output clamp current |
VO < 0 |
|
–50 |
mA |
| IO |
Continuous output current |
|
±50 |
mA |
|
Continuous current through each VCCA or
GND |
|
±100 |
mA |
| Tstg |
Storage temperature range |
–65 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause
permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated
under Recommended Operating Conditions is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device
reliability.
(2) This value is limited to 6V maximum.