SCASE82 January   2026 TPUL2T122-Q1

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Thermal Information
    4. 5.4 Electrical Characteristics
    5. 5.5 Recommended Operating Conditions
    6. 5.6 Timing Characteristics
    7.     13
    8. 5.7 Switching Characteristics
    9. 5.8 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
      1. 7.1.1 State Machine Description
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Naming Convention
      2. 7.3.2 Retriggerable One-Shot
      3. 7.3.3 Timing Mechanism and Accuracy
      4. 7.3.4 Balanced CMOS Push-Pull Outputs
      5. 7.3.5 CMOS Schmitt-Trigger Inputs
      6. 7.3.6 Latching Logic with Known Power-Up State
      7. 7.3.7 Reduced Input Threshold Voltages
      8. 7.3.8 Wettable Flanks
      9. 7.3.9 Clamp Diode Structure
    4. 7.4 Device Functional Modes
      1. 7.4.1 Off-State Operation
      2. 7.4.2 Startup Operation
      3. 7.4.3 On-State Operation
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application - Edge Detector
      1. 8.2.1 Design Requirements
        1. 8.2.1.1 Timing Components
        2. 8.2.1.2 Input Considerations
        3. 8.2.1.3 Output Considerations
        4. 8.2.1.4 Power Considerations
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curves
    3. 8.3 Typical Application - Delayed Pulse Generator
      1. 8.3.1 Application Curves
    4. 8.4 Power Supply Recommendations
    5. 8.5 Layout
      1. 8.5.1 Layout Guidelines
      2. 8.5.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

On-State Operation

The table below lists the on-state functional modes for the TPUL2T122x-Q1.

Table 7-2 TPUL2T122-Q1 Function Table
INPUTS(1) OUTPUTS(2)
CLR T T Q Q
L X X L H
H H X L(3) H(3)
H X L L(3) H(3)
H L TPUL2T122-Q1 TPUL2T122A-Q1 (4) TPUL2T122-Q1 TPUL2T122A-Q1 (4)
H H TPUL2T122-Q1 TPUL2T122A-Q1 (4) TPUL2T122-Q1 TPUL2T122A-Q1 (4)
Table 7-3 TPUL2T122A-Q1 Function Table
INPUTS(1) OUTPUTS(2)
CLR T T Q Q
L X X L H
H L X L(3) H(3)
H X H L(3) H(3)
H H TPUL2T122-Q1 TPUL2T122A-Q1 (4) TPUL2T122-Q1 TPUL2T122A-Q1 (4)
H L TPUL2T122-Q1 TPUL2T122A-Q1 (4) TPUL2T122-Q1 TPUL2T122A-Q1 (4)
H = high voltage level, L = low voltage level, X = don't care
L = driving low, H = driving high, TPUL2T122-Q1 TPUL2T122A-Q1 = driving high for the defined pulse width time, TPUL2T122-Q1 TPUL2T122A-Q1 = driving low for the defined pulse width time
These outputs are based on the assumption that the indicated steady-state conditions at the inputs have been set up long enough to complete any output pulse.
If an output pulse is triggered while a previous output pulse is still active, the output continues to drive high for one additional pulse width.