SCES982A May 2026 – June 2026 TXB0606
PRODUCTION DATA
| PARAMETER | FROM | TO | TEST CONDITIONS | LOAD | B-Port Supply Voltage (VCCB) | UNIT | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.8 ± 0.15V | 2.5 ± 0.2V | 3.3 ± 0.3V | |||||||||||||
| MIN | TYP | MAX | MIN | TYP | MAX | MIN | TYP | MAX | |||||||
| tPHL | Propagation Delay (High-to-Low) | A | B | -40°C to 85°C | CL =15pF | 4 | 11.3 | 3.3 | 7.2 | 2.9 | 5.8 | ns | |||
| -40°C to 85°C | CL =100pF | 5.7 | 16 | 4.6 | 10.4 | 4.1 | 8.3 | ||||||||
| -40°C to 125°C | CL =15pF | 4.4 | 11.6 | 3.3 | 7.2 | 2.9 | 5.8 | ns | |||||||
| -40°C to 125°C | CL =100pF | 5.7 | 16 | 4.6 | 10.4 | 4.1 | 8.3 | ||||||||
| tPLH | Propagation Delay (Low-to-High) | -40°C to 85°C | CL =15pF | 4.2 | 12.4 | 3.5 | 7.9 | 3.1 | 6.3 | ns | |||||
| -40°C to 85°C | CL =100pF | 6.2 | 16.3 | 5 | 10.8 | 4.5 | 8.8 | ||||||||
| -40°C to 125°C | CL =15pF | 4.2 | 12.4 | 3.5 | 7.9 | 3.1 | 6.3 | ns | |||||||
| -40°C to 125°C | CL =100pF | 6.2 | 16.3 | 5 | 10.8 | 4.5 | 8.8 | ||||||||
| tPHL | Propagation Delay (Hight-to-Low) | B | A | -40°C to 85°C | CL =15pF | 2.8 | 6.3 | 2.4 | 4.6 | 2.2 | 3.9 | ns | |||
| -40°C to 85°C | CL =100pF | 4 | 7.8 | 3.6 | 6 | 3.4 | 5.4 | ||||||||
| -40°C to 125°C | CL =15pF | 2.8 | 6.3 | 2.4 | 4.6 | 2.2 | 3.9 | ns | |||||||
| -40°C to 125°C | CL =100pF | 4 | 7.8 | 3.6 | 6 | 3.4 | 5.4 | ||||||||
| tPLH | Propagation Delay (Low-to-High) | -40°C to 85°C | CL =15pF | 2.7 | 5.8 | 2.3 | 4.4 | 2.2 | 3.8 | ns | |||||
| -40°C to 85°C | CL =100pF | 3.9 | 7.4 | 3.6 | 5.9 | 3.4 | 5.3 | ||||||||
| -40°C to 125°C | CL =15pF | 2.7 | 5.8 | 2.3 | 4.4 | 2.0 | 3.8 | ns | |||||||
| -40°C to 125°C | CL =100pF | 3.9 | 7.4 | 3.6 | 5.9 | 3.4 | 5.3 | ||||||||
| tDCW | Direction Change Wait Time | A or B | B or A | 40 | 30 | 27 | ns | ||||||||
| ten | Enable Time | OE | A or B | -40°C to 125°C | 354 | 324 | 318 | ns | |||||||
| A or B | -40°C to 125°C | 408 | 313 | 290 | |||||||||||
| tdis | Disable Time | A or B | -40°C to 125°C | 99 | 100 | 100 | |||||||||
| A or B | -40°C to 125°C | 95 | 97 | 97 | |||||||||||
| trA ,tfA | Ouput Rise/ Fall Time |
B | A | -40°C to 85°C | CL =15pF | 0.8 | 0.8 | 0.8 | ns | ||||||
| -40°C to 85°C | CL =100pF | 6.6 | 6.7 | 6.7 | |||||||||||
| -40°C to 125°C | CL =15pF | 1.1 | 1.1 | 1.1 | |||||||||||
| -40°C to 125°C | CL =100pF | 6.6 | 6.7 | 6.7 | |||||||||||
| trB ,tfB | Ouput Rise/ Fall Time |
A | B | -40°C to 85°C | CL =15pF | 2.8 | 2.4 | 1 | ns | ||||||
| -40°C to 85°C | CL =100pF | 11.8 | 8.2 | 7 | |||||||||||
| -40°C to 125°C | CL =15pF | 2.8 | 2.4 | 1.5 | |||||||||||
| -40°C to 125°C | CL =100pF | 14.0 | 9.9 | 8.9 | |||||||||||
| tsk(o) | Channel-to-channel skew | A or B | B or A | -40°C to 125°C |
CL =15pF | 0.6 | 0.6 | 0.6 | ns | ||||||
| ZOS,A | One-Shot Impedance | A or B | A or B | 28 | 22 | 21 | Ω | ||||||||
| Data Rate | Maximum data rate | A or B | B or A | CL =15pF (1) | 120 | 160 | 139 | 190 | 138 | 146 | Mbps | ||||
| A or B | B or A | CL =100pF (1) | 80 | 102 | 90 | 120 | 109 | 127 | Mbps | ||||||