SDAA393 June   2026 AM2431 , AM2432 , AM2434

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Functional Safety Fundamentals
    1. 1.1 What is Functional Safety
    2. 1.2 Causality Chain from Fault to Harm
    3. 1.3 Core Problems Addressed by Functional Safety
  5. 2Safety Standards and Grade Classification
    1. 2.1 Major Safety Standard Systems
    2. 2.2 Functional Safety in Industrial Communication (FSoE)
    3. 2.3 Safety Grade Indicator System
      1. 2.3.1 IEC 61508 - Safety Integrity Level (SIL)
      2. 2.3.2 ISO 13849-1 - Performance Level (PL) and Category (CAT)
  6. 3System Safety Goal Decomposition
    1. 3.1 HARA Process and Safety Goal Definition
    2. 3.2 Safety Goal Decomposition and ASIL/SIL Assignment
    3. 3.3 Concrete Application of System-Level Decomposition
    4. 3.4 Role and Responsibility Division
  7. 4TI Chip Safety Architecture
    1. 4.1 MCU-Level Safety Architecture
    2. 4.2 Integrated Safety Mechanisms/Technology in TI MCU/MPU
      1. 4.2.1 Freedom From Interference (FFI) Design
      2. 4.2.2 Memory Protection and ECC Technology
      3. 4.2.3 Other Integrated Safety Mechanisms
  8. 5Functional Safety PLC Architecture Design
    1. 5.1 Necessity and Application Scenarios of Functional Safety PLC
    2. 5.2 Functional Safety PLC Architecture Design
    3. 5.3 Design Implementation Cases
    4. 5.4 TI Functional Safety Design Resources
  9. 6Summary
  10. 7References

Functional Safety in Industrial Communication (FSoE)

The widespread adoption of Industrial Ethernet brings new challenges: the need to achieve determinism and safety on standard networks.

 FSoE protocol hierarchy structure Figure 2-1 FSoE protocol hierarchy structure
  • Application layer: safety-related data (position, velocity, fault codes, etc.)
  • FSoE Protocol layer:
    • Sequence number detection (detects duplication, loss, out-of-order)
    • CRC verification (detects data corruption)
    • Connection ID (detects incorrect forwarding)
    • Watchdog timer (detects timeout delays)
  • Physical layer: standard Ethernet MAC/PHY

FSoE does not modify the underlying physical layer, it enhances through application layer protocol.

Figure 3 Differences between FSoE and Standard PLC Communication

Characteristic Standard Ethernet/EtherCAT FSoE Enhancement
Base protocol EtherCAT standard Same
Safety data No special processing With CRC and sequence number
Fault detection Packet loss detection Complete FSoE diagnostics
Delay detection None Watchdog monitoring
Reliability Medium (network dependent) High (automatic fault transfer)
Application complexity Low Medium (protocol stack processing)