Driver Disable Timing

A key parameter for understanding the glitch is the driver disable time. Ideally, switching from transmit mode to receive mode has no switching time, but that's impossible for actual analog device. For THVD4431A, the typical driver disable time is around 65ns. This switching time results in turn-off of the RS-485 driver, which can generate significant di/dt when inductive elements are present on the bus.