over operating free-air temperature range (unless otherwise noted)(1) (2) | MIN | MAX | UNIT |
|---|
| VCC | Supply voltage range | –0.3 | 6 | V |
| V(A), V(B), V(Y), V(Z) | Voltage range at
any bus terminal (A, B, Y, Z) | –9 | 14 | V |
| V(TRANS) | Voltage input,
transient pulse through 100Ω (see Figure 7-12) (A, B, Y, Z)(3) | –50 | 50 | V |
| VI | Input voltage range
(D, DE, RE) | –0.5 | 7 | V |
| PD(cont) | Continuous total
power dissipation | Internally limited(4) | |
| IO | Output current
(receiver output only, R) | | 11 | mA |
| TJ | Junction
temperature | | 165 | °C |
| Tstg | Storage temperature
range | –65 | 150 | °C |
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.