SLASF96 April 2024 AFE20408
PRODUCTION DATA
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| BCEN_DACB3 | BCEN_DACB2 | BCEN_DACB1 | BCEN_DACB0 | BCEN_DACA3 | BCEN_DACA2 | BCEN_DACA1 | BCEN_DACA0 |
| R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| SYNCEN_ DACB3 |
SYNCEN_ DACB2 |
SYNCEN_ DACB1 |
SYNCEN_ DACB0 |
SYNCEN_ DACA3 |
SYNCEN_ DACA2 |
SYNCEN_ DACA1 |
SYNCEN_ DACA0 |
| R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15 | BCEN_DACB3 | R/W | 0h | DAC broadcast enable. 0: Ignores broadcast writes on this DAC 1: Allow broadcast writes on this DAC |
| 14 | BCEN_DACB2 | R/W | 0h | |
| 13 | BCEN_DACB1 | R/W | 0h | |
| 12 | BCEN_DACB0 | R/W | 0h | |
| 11 | BCEN_DACA3 | R/W | 0h | |
| 10 | BCEN_DACA2 | R/W | 0h | |
| 9 | BCEN_DACA1 | R/W | 0h | |
| 8 | BCEN_DACA0 | R/W | 0h | |
| 7 | SYNCEN_DACB3 | R/W | 0h | DAC synchronous
configuration. 0: Set DAC into asynchronous mode. 1: Set DAC into synchronous mode. |
| 6 | SYNCEN_DACB2 | R/W | 0h | |
| 5 | SYNCEN_DACB1 | R/W | 0h | |
| 4 | SYNCEN_DACB0 | R/W | 0h | |
| 3 | SYNCEN_DACA3 | R/W | 0h | |
| 2 | SYNCEN_DACA2 | R/W | 0h | |
| 1 | SYNCEN_DACA1 | R/W | 0h | |
| 0 | SYNCEN_DACA0 | R/W | 0h |