| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| RESERVED | |||||||
| R-0h | |||||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED | ADC_BYP_EN | ALARM_BYP_EN | |||||
| R-0h | R/W-0h | R/W-0h | |||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 1 | ADC_BYP_EN | R/W | 0h | ADC data bypass enable. Bypasses all ADC conversion
results. 0: Bypass disabled. 1: All ADC conversion data are bypassed, with data registers forced to the value stored in ADC_BYP (see Section 7.3.1.4). |