SLAU546A March   2014  – October 2021 TRF37A73 , TRF37A75 , TRF37B73 , TRF37B75 , TRF37C73 , TRF37C75 , TRF37D73

 

  1. 1Contents
  2. 2EVM Overview
    1. 2.1 Schematic and BOM
    2. 2.2 TRF37x73/75 EVM Bill of Material
    3. 2.3 General Usage Information
  3. 3EVM Layout
    1. 3.1 Description: Stack up and Material
    2. 3.2 PCB Layers
  4. 4EVM Board Loss
  5. 5Test Block Diagrams
    1. 5.1 Noise Figure
    2. 5.2 Gain and P1dB
    3. 5.3 OIP3
  6. 6Revision History

Gain and P1dB

Recommendations and comments:

  1. Take into account losses of coax and attenuators to and from the EVM board
  2. Take into account losses of traces on the board up to the I/O pins of the DUT
  3. Power meters are typically a few tenths of dB more accurate than a signal generator's level controls and spectrum analyzer measurement capability. For precise measurements, use a power meter to measure the output of the signal generator and output of the TRF37x73/75 EVM.
GUID-0A1B0B0B-1C80-4AB3-A06D-7FAC49C3C031-low.gif