SLIS095B March   2000  – March 2025 TPIC6B596

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Application
  4. 3 Description
  5. 4 Pin Configuration and Functions
  6. 5 Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Dissipation Rating Table
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Electrical Characteristics
    5. 5.5 Switching Characteristics
    6. 5.6 Thermal Resistance
    7. 5.7 Typical Characteristics
  7. 6 Parameter Measurement Information
  8. 7 Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Reference
      1. 7.3.1 Reference
      2. 7.3.2 Clear Register
      3. 7.3.3 Output Control
      4. 7.3.4 Cascaded Application
      5. 7.3.5 Current Limit Function
  9. 8 Device Functional Modes
    1. 8.1 Operating with Vcc < 4.5V
    2. 8.2 Operating with 5.5V < Vcc ≤ 7V
  10. 9 Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Parameter Measurement Information

TPIC6B596 Resistive-Load Test Circuit
                    and Voltage Waveforms
The word generator has the following characteristics: tr ≤ 10ns, tf ≤ 10ns, tw = 300ns, pulsed repetition rate (PRR) = 5kHz, ZO = 50Ω.
CL includes probe and jig capacitance.
Write data and read data are valid only when RCK is low
Figure 6-1 Resistive-Load Test Circuit and Voltage Waveforms
TPIC6B596 Test Circuit, Switching Times,
                    and Voltage Waveforms
The word generator has the following characteristics: tr ≤ 10ns, tf ≤ 10ns, tw = 300ns, pulsed repetition rate (PRR) = 5kHz, ZO = 50Ω.
CL includes probe and jig capacitance
Figure 6-2 Test Circuit, Switching Times, and Voltage Waveforms
TPIC6B596 Reverse-Recovery-Current Test
                    Circuit and Waveforms of Source-to-Drain Diode
The DRAIN terminal under test is connected to the TP K test point. All other terminals are connected together and connected to the TP A test point.
The VGG amplitude and RG are adjusted for di/dt = 20A/µs. A VGG double-pulse train is used to set IF = 0.1A, where t1 = 10µs, t2 = 7µs, and t3 = 3µs.
Figure 6-3 Reverse-Recovery-Current Test Circuit and Waveforms of Source-to-Drain Diode
TPIC6B596 Single-Pulse Avalanche Energy
                    Test Circuit and Waveforms
The word generator has the following characteristics: tr ≤ 10ns, tf ≤ 10ns, ZO = 50Ω.
Input pulse duration, tw, is increased until peak current IAS = 0.5A.
Energy test level is defined as EAS = IAS x V(BR)DSX x tav/2 = 30mJ.
Figure 6-4 Single-Pulse Avalanche Energy Test Circuit and Waveforms
TPIC6B596 Maximum Continuous Drain
                    Current of Each Output vs Number of Outputs Conducting Simultaneously Figure 6-5 Maximum Continuous Drain Current of Each Output vs Number of Outputs Conducting Simultaneously
TPIC6B596 Maximum Peak Drain Current of
                    Each Output vs Number of Outputs Conducting Simultaneously Figure 6-6 Maximum Peak Drain Current of Each Output vs Number of Outputs Conducting Simultaneously