SLLSEP1C July 2015 – July 2025 ISO7810
PRODUCTION DATA
Table 7-2 lists the ISO7810x functional modes.
| VCC1 | VCC2(1) | INPUT (IN)(3) | OUTPUT (OUT) | COMMENTS |
|---|---|---|---|---|
| PU | PU | H | H | Normal Operation: A channel output assumes the logic state of the input. |
| L | L | |||
| Open | Default | Default mode: When IN is open, the corresponding channel output goes to the default logic state. Default = High for ISO7810 and Low for ISO7810F. | ||
| PD | PU | X | Default | Default mode: When VCC1 is unpowered, a channel output assumes the logic state based on the selected default option. Default = High for ISO7810 and Low for ISO7810F. When VCC1 transitions from unpowered to powered-up, a channel output assumes the logic state of the input. When VCC1 transitions from powered-up to unpowered, channel output assumes the selected default state. |
| X | PD | X | Undetermined | When VCC2 is
unpowered, a channel output is undetermined (2). When VCC2 transitions from unpowered to powered-up, a channel output assumes the logic state of the input |