In the below images, VCCI and
VCCO refers to the power supplies VIO and VISOIN,
respectively.
A. CL = 15pF and The
input pulse is supplied by a generator having the following characteristics: PRR
≤ 50kHz, 50% duty cycle, tr ≤ 3ns, tf ≤ 3ns, ZO
= 50Ω. At the input, 50Ω resistor is required to terminate Input Generator
signal. The 50Ω resistor is not needed in actual application.
B. B. CL = 15pF and
includes instrumentation and fixture capacitance within ±20%.
Figure 6-1 Switching
Characteristics Test Circuit and Voltage Waveforms
A. A. The input pulse is supplied by
a generator having the following characteristics: PRR ≤ 50kHz, 50% duty cycle,
tr ≤ 3ns, tf ≤ 3ns, ZO = 50Ω. At the input,
the 50Ω resistor is required to terminate Input Generator signal. the 50Ω
resistor is not needed in actual application.
B. B. CL = 15pF and
includes instrumentation and fixture capacitance within ±20%.
Figure 6-2 Enable/Disable Propagation
Delay Time Test Circuit and Waveform
Note: A. CL = 15pF and
includes instrumentation and fixture capacitance within ±20%.
Note: B. Power Supply Ramp Rate =
10mV/ns.
Figure 6-3 Default Output Delay Time Test Circuit and Voltage Waveforms
Note: CL = 15pF and
includes instrumentation and fixture capacitance within ±20%.
Note: Pass-fail criteria: Outputs must remain stable.
Figure 6-4 Common-Mode Transient Immunity Test Circuit