Design to External Circuit for Solving ZCS Issue at Burst Transition Period

The auto standby circuitry below makes sure that the minimum burst off is 200µs when the switching node is damped, and the first pulse of the burst packet turns on without ZCS. Figure 5-1 shows how to minimize the ZCS issue at burst transition period with auto standby external circuit.

The following list details the operating mechanism for external auto standby circuit with the UCC256404.

  1. Use circuit to automatically turn on PFC and disable burst mode at higher load condition.
  2. INA boosts voltage across current sense on output power rail
  3. Comparator output is high when INA output is greater than reference voltage, Small FET turn on sends fault signal to primary side at LL/SS pin.
  4. Disables burst mode as load gets larger to make sure minimum time is kept between burst packets
 External Auto Standby Circuit With UCC256404Figure 5-1 External Auto Standby Circuit With UCC256404