SLUS987C January 2011 – December 2019 BQ33100
PRODUCTION DATA.
The BQ33100 comes programmed to support 4-series capacitor systems with cell balancing enabled. Table 95 shows other key configuration defaults.
| DESIGN PARAMETER | EXAMPLE VALUE |
|---|---|
| Number of Series Cells | 4 |
| Design Capacitance | 250 F |
| Design ESR | 320 mΩ |
| Cell Balancing | Enabled |
| V Chg Nominal | 8400 mV |
| V CHG A | 8900 mV |
| V CHG | 9500 mV |
| V CHG MAX | 10000 mV |
| Learn Frequency | 2 weeks |
| Learn Delta Voltage | 500 mV |
Use the BQEVSW tool to update the settings to meet the specific application or pack configuration requirements.