8.5.2.2.12.3 SafetyStatus (0x51)
This read-word function returns the status of the safety features. These flags do not cause the FAULT pin to be set unless the corresponding bit in FAULT is set.
Table 57. SafetyStatus
| SBS CMD |
MODE |
NAME |
FORMAT |
SIZE IN BYTES |
MIN VALUE |
MAX VALUE |
DEFAULT VALUE |
UNIT |
| 0x51 |
R |
SafetyStatus |
hex |
2 |
0x0000 |
0xffff |
— |
|
Figure 8. SafetyStatus Registers
| 15 |
14 |
13 |
12 |
11 |
10 |
9 |
8 |
| CLBAD |
HFAIL |
HWARN |
HLOW |
RSVD |
OT |
CIM |
OV |
| 7 |
6 |
5 |
4 |
3 |
2 |
1 |
0 |
| DFF |
RSVD |
AFE_C |
WDF |
OCC |
OCD |
SCC |
SCD |
LEGEND: All values are read-only.
CLBAD1 = Excessive capacitor leakage fault
HWARN1 = Health low warning
HLOW1 = Health low indication
OT1 = Charge overtemperature fault
CIM1 = Capacitor voltage Imbalance fault
OV1 = Capacitor overvoltage fault
DFF1 = Data flash fault permanent failure fault
AFE_C1 = Permanent AFE Communications failure fault
WDF1 = AFE watchdog fault
OCC1= Overcurrent during charge fault
OCD1= AFE overcurrent during discharge fault
SCC1= AFE short circuit during charge fault